A fused cast AZS block can look qualified from the outside, but that does not guarantee internal reliability. For critical glass furnace zones, the size and position of internal shrinkage voids can directly affect furnace campaign life and glass leakage risk.

 

1. Internal Voids Are a Hidden Quality Risk

 

During fused casting, AZS blocks go through a special solidification process. Chemical segregation, uneven density, and internal shrinkage voids may occur inside the block. Two blocks with similar appearance and density can still have very different void positions and void sizes inside.

For glass furnaces, the size and position of shrinkage voids affect block reliability under molten glass flow, thermal stress, and long-term corrosion, especially in sidewalls, bottoms, throats, weirs, corner blocks, and other critical zones.

Finished AZS blocks prepared for inspection and pre-assembly

Cut-open AZS block comparison: internal void size and position are key quality factors

 

2. Appearance and Weight Are Not Enough

 

Laboratory sample preparation supports data-based quality evaluation
info-1446-1206

info-1446-700


Blocks with similar appearance and density may still have different internal void positions
info-1446-742

 

Traditional methods for checking internal voids include cutting the block, ultrasonic testing, and weighing. Each has limitations: cutting is destructive and only works as sampling; ultrasonic testing is time-consuming and difficult for routine online control; weighing is simple, but it cannot locate the exact position of an internal void.

Therefore, when purchasing AZS blocks for critical furnace zones, buyers should not rely only on appearance, weight, or average density. They should check whether the supplier has non-destructive internal flaw detection capability.

 

Comparison of Inspection Methods

 

Method

Advantage

Limitation

Cut-open inspection

Directly shows internal structure

Destructive sampling; cannot inspect every block

Ultrasonic testing

Can detect internal conditions

Time-consuming and less suitable for routine online control

Weighing method

Simple and intuitive

Cannot locate the exact void position

Radar flaw detection

Non-destructive; helps locate internal void distribution

Requires software conversion and long-term comparison experience

 

 

3. Radar Inspection Helps See Inside the Block

 

Shrinkage void position and size confirmation for near-void-free cast AZS blocks

info-1600-900

Customer visit: radar inspection process shown on-site

info-1446-669

 

GSSI radar inspection demonstration for AZS internal quality control

info-1446-858

 

Radar inspection process for AZS blocks in the factor

info-1446-600

 

Radar image and cut-open comparison help build reliable internal quality judgment

info-1200-557

 

Radar inspection is not just about obtaining an internal image of the block. The raw radar image must be integrated and converted by software, then correlated with long-term cut-open comparison tests to build accurate judgment criteria.
Through long-term cut-open analysis and radar image comparison across different production batches, Dezhong has built practical data experience, allowing radar images to correspond more accurately to internal shrinkage void distribution.

 

4. Critical Furnace Zones Need Stricter Inspection

 

Corrosion comparison under different furnace types and operating conditions
Pre-assembled furnace blocks help verify dimensions, numbering, and installation sequence

In glass furnaces, corner blocks, weir blocks, throat cover blocks, sidewall blocks for ultra-clear glass furnaces, and bottom areas with heavy electric boosting are exposed to higher temperature, stronger flow, and more severe corrosion.

If blocks with poor internal casting quality or unfavorable void positions are used in these zones, they may increase the risk of local corrosion, glass leakage, and furnace shutdown. Therefore, blocks for critical areas should be inspected internally and graded before use.

 

5. Inspection Is Not Only for Rejecting Defects

 

Radar inspection result analysis supports product grading and position matching

info-1011-629

 

Post-campaign photo: poor internal casting quality can increase critical-zone risk

info-1213-384

Timely internal inspection can remove products with obvious risks, but it can also grade acceptable products by quality. This allows the factory to place the best blocks in the most critical furnace positions and use lower-risk products in less demanding areas.

This logic of inspection, grading, and matching blocks to furnace zones is one of the most important methods for protecting furnace campaign life. It is closer to real service performance than relying only on chemical composition reports.

 

6. What Buyers Should Ask Before Ordering

 

When purchasing fused cast AZS blocks, especially for sidewalls, bottoms, throats, weirs, corners, and other critical zones, buyers should ask the supplier about its internal flaw detection method, inspection records, grading standard, and pre-shipment quality control process.

 

 

Why Work with Dezhong

 

Customer site inspection and technical discussion strengthen trust in factory quality control

Dezhong combines fused cast AZS production experience with in-house quality inspection capability, including Rigaku XRF, glass phase exudation testing, static and dynamic molten glass corrosion testing, bulk density and apparent porosity testing, GSSI radar flaw detection, and factory pre-assembly.


If your project involves AZS block selection for sidewalls, bottoms, throats, weirs, corners, or other critical furnace zones, send us your furnace drawing or application requirements. We can help recommend suitable products and inspection solutions.


Send us your furnace drawing, application zone, or current block requirement. Dezhong can recommend suitable AZS products and internal flaw detection solutions according to critical-zone risk.


 